TEMPERATURES OPTIMIZATION OF TWO-CIRCUIT CLOSED COOLING SYSTEM OF SHIP'S POWER PLANT

Abstract

    The issues of creating environmentally friendly highly reliable closed-loop cooling systems are considered in the paper. The achievement of these qualities is ensured by the rejection of cooling water intake. The analysis of various coolants of the power installation requiring cooling is carried out. It is shown that for the cooling of a number of coolants it is advisable to create double-circuit cooling systems. This requires the introduction of an additional heat exchanger and the separation of the temperature head between the cooled coolant and seawater. The authors suggest an approach that makes it possible to distribute this temperature head between the circuits optimally. This procedure involves comparing various heat exchangers based on their reduced area. A nomogram is presented to determine the optimal value of the temperature head.

Keywords: cooling system, marine power plant, temperature head, heat exchanger, heat transfer coefficient

References

Шурпяк В.К. Учет особенностей систем охлаждения при оценке энергетической эффективности судов/ В.К. Шурпяк // Научно-техн. сб. Российского морского регистра судоходства. – 2014. – Вып. 37. – С. 51–55.

Walter H., Keel Coolers, [Электронный ресурс]. – Режим доступа: http://www.waltergear.com/ kc.htm (дата обращения: 11.11.2018).

Specifying a Trawler. [Электронный ресурс]. – Режим доступа: http://bluewater-trawlers. blogspt.com/2008/11/hull-construction.html (дата обращения: 12.11.2018).

Specialty Gridcooler Keel Coolers. [Электронный ресурс] Режим доступа: http://www.fernstrum. com/products/gridcooler-keel-cooler/specialty-coolers (дата обращения: 13.11.2018).

Duramax DuraCooler Patented Streamlined Header Design. [Электронный ресурс] Режим доступа: http://www.duramaxmarine.com/heat-duracooler.htm (дата обращения: 10.11.2018).

Drydocking Services. [Электронный ресурс] Режим доступа: http://www.diversifiedmarineinc.com /Drydock.htm (дата обращения: 17.11.2018)

Федоровский К.Ю. Замкнутая система охлаждения плавкрана грузоподъемностью 500 т / К.Ю. Федоровский, Н.М. Туриченко // Судостроение. – 1987. – № 12. – С. 15–17.

Walter H., W. Witt. «Forschritte de ragger-und SchiffbautechnicbeimHopperbagger «Ludwig Franzius» der Wasser-und Schiffahrtsverwaltung», Schiff und Hafen. – 1965. – №17. – Рp. 595–610.

Bobotek J. «Wymianaciepla w chlodnicachposzyciowych», BudownictwoOkretowe. – 1976. – Kwiecjen. – Pp. 122–124.

The International Convention for the Prevention of Pollution of Ships (MARPOL73/78). [Электронный ресурс] Режим доступа: http://marineandmaritimetechnology.blogspot.com/2017/11/ summary-of-marpol-international.html (дата обращения: 08.11.2018).

Гарбаненко О.К. оснащение водозаборов морских нефгазодобывающих платформ рыбозащитными устройствами [Электронный ресурс]. – Режим доступа: http://helion-ltd.ru/s-m-part-2/3713-2009-10-14-18-33-05/. (дата обращения: 11.08.2016).

Ващинников А.Е. Новые направления в разработке сетчатых рыбозащитных устройств / А.Е. Ващинников, А.А. Васильев, К.В. Илюшин, В.Д. Шульгин // Материалы докладов 4-й Всерос. конф. с международным участием. – Борок: Акварос, 2010. – С. 9–13.

Краткая историческая экология: регуляция численности популяций в биоценозах [Электронный ресурс]. – Режим доступа: http://helpiks.org/6-1866.html. (дата обращения: 17.011.2018)

Предварительные материалы по оценке воздействия на окружающую среду эксплуатации энергоблока 2 и 3 Калининской АЭС на мощности реакторной установки 104% от номинальной / ООО «Гидротехпроект». – Тверь, 2013. – 333 с.

Author Biographies

Konstantin Yu. Fedorovskiy , Sevastopol State University, Sevastopol, Russia

Doctor of Technical Sciences, Professor, Head of the Department «Power Installations of Ships and Structures», Sevastopol State University (FGAOU VO «SevSU»), Maritime Institute, 33, Universitetskaya st., Sevastopol, 299053, Russia, e-mail: fedkonst@rambler.ru

Nadezhda K. Fedorovskaya , Sevastopol State University, Sevastopol, Russia

Post-graduate student of the department «Power installations of marine vessels and structures», Sevastopol State University (FGAOU VO «SevSU»), Maritime Institute, 33, Universitetskaya st. Sevastopol, 299053, Russia, e-mail: n.fedorovskaya14@mail.ru

Published
10-03-2020
How to Cite
Fedorovskiy, K. Y., & Fedorovskaya, N. K. (2020). TEMPERATURES OPTIMIZATION OF TWO-CIRCUIT CLOSED COOLING SYSTEM OF SHIP’S POWER PLANT. Russian Journal of Water Transport, (62), 175-183. https://doi.org/10.37890/jwt.vi62.48
Section
Operation of ship power equipment